Supported acquisition devices

The Dentrix Imaging Center supports the following acquisition devices.

Intraoral X-ray devices

·        Acteon Sopro SOPIX (supported directly or via a TWAIN driver)

·        Apteryx Tuxedo sensor (supported using e2v as the acquisition device) or (previous version is Hamamatsu, which is also supported directly)

Note: Tuxedo sensors that were manufactured prior to 2019 are Hamamatsu devices (LED Dental Tuxedo sensors), which are supported using Hamamatsu as the acquisition device. Contact LED Dental to verify if your Tuxedo sensor is a Hamamatsu device or an e2v device.

·        Brassler GEM sensor

·        CARINA sensor

·        DentalSensors.com Apex

·        Dentimax Dream sensor (supported using e2v as the acquisition device)

·        Dentsply Sirona XIOS XG

·        Dentsply Sirona XIOS AE and Schick AE

·        DEXIS Platinum

·        DEXIS Titaninum

·        DUO sensor

·        EVA Select sensor (supported using e2v as the acquisition device)

·        FTG DC-Air/CEFLA

·        GEM sensor

·        Gendex/KaVo IO (supported using the GxPicture acquisition device)

·        Gendex GXS-700

·        Gendex Visualix eHD (only compatible with Windows 7)

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging Center on a computer running Windows 7.

·        Gendex Visualix GX-S

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging Center on a computer running Windows XP.

·        Hamamatsu

Note: Tuxedo sensors manufactured prior to 2019 are Hamamatsu devices.

·        Handy sensor

·        ImageWorks EVA Select (supported directly as an e2v sensor or via a TWAIN driver)

·        InstaRay sensor (supported using Hamamatsu as the acquisition device)

·        Jazz (supported via a TWAIN driver)

·        Jazz Solo sensor

·        KaVo Dig eXam

·        KaVo IXS

·        Kodak/Carestream 5000 series and 6000 series (supported directly or via a TWAIN driver)

·        LED Dental Tuxedo (supported using Hamamatsu as the acquisition device)

Note: Tuxedo sensors manufactured in or before 2019 are e2v devices (Apteryx Tuxedo sensors), which are supported using e2v as the acquisition device. Contact LED Dental to verify if your Tuxedo sensor is a Hamamatsu device or an e2v device.

·        Midmark Progeny ClearVision (supported directly or via a TWAIN driver)

·        Owandy ONE and OPTEO

·        Planmeca ProSensor (supported via DIDAPI)

·        Planmeca ProSensor HD (supported via DIDAPI)

·        Polaroid KEREN HD-S (supported via a TWAIN driver)

·        QuickRay (supported using e2v as the acquisition device)

·        QuickRay HD sensor (supported using Hamamatsu as the acquisition device)

·        Remedi (supported using Hamamatsu as acquisition device)

·        Schick (supported via a TWAIN driver)

·        Schick 33/Xios XG (supported directly or via a TWAIN driver)

Note: The device filter defaults are set automatically. When you select the Schick 33 device for the first time, the following default settings are used for filtering: custom Schick filter is set to "General," Apply Enhancement is set to "Not Enhanced," and Schick 33 is set to "Binned" operation.

·        Schick AE (Dentsply Sirona)

·        Schick CDR/Elite (supported directly or via a TWAIN driver; only compatible with Windows 7 32-bit)

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging Center on a computer running Windows 7 32-bit.

·        Sirona/Schick USB 3/AE (supported directly or via a TWAIN driver) – Added image filtering options during image acquisition. These filtering options enhance the flexibility and quality control available to users when they are capturing images.

·        Schick HS (supported directly or via a TWAIN driver)

·        Sirona IOSS – Added sharpness settings for filters. Filters for the Supreme and Velocity family of sensors allow users to set a sharpness value between 0 and 100. A new Sirona section was added to the agent preferences to store these values.

·        SOPIX Gen 2 sensors

·        SOTA Clio/Clio prime sensor (supported using e2v as the acquisition device)

·        Suni (most models supported via a TWAIN driver; contact the support department to verify)

·        Teledyne e2v

Note: e2v sensors are rebranded and sold by many companies under their specific brand names. The following devices are supported using e2v as the acquisition device:

·        Apteryx Tuxedo sensor (previous version is Hamamatsu, which is also supported directly)

·        Dentimax Dream sensor

·        EVA Select sensor

·        QuickRay sensor

·        SOTA Clio/Clio Prime sensor

·        XDR X-ray sensor

·        Vatech HD sensor (supported via a TWAIN driver or Vatech EzDent-i Software Bridge)

·        Vatech Wave sensor (supported via a TWAIN driver or Vatech EzDent-i Software Bridge)

·        Video Dental Concepts QuickRay HD

·        XDR sensor

·        XDR X-ray sensor (supported using e2v as the acquisition device)

·        Carestream Imaging Software Bridge

·        DEXIS Software Bridge

·        DTX Studio Software Bridge

·        ImageWorks Software Bridge

·        J. Morita i-Dixel Software Bridge

·        Romexis Software Bridge

·        ShadeWave Bidirectional Software Bridge

·        Sidexis Software Bridge

·        Vatech EzDent-i Software Bridge

·        File Import (.bmp, .png, .jpg, .tif )

Intraoral/extraoral X-ray Phosphor Plate devices

·        Acteon Sopro PSPIX

·        Air Techniques ScanX Classic

·        Air Techniques ScanX Duo

·        Air Techniques ScanX IO

·        Air Techniques ScanX Swift

·        Durr VistaScan (supported directly or via a TWAIN driver)

Note: You can use VisionX Connect to acquire images on a computer running Windows 11.

·        Durr VistaScan Combi+ (supported directly or via a TWAIN driver)

·        Durr VistaScan Mini (supported directly or via a TWAIN driver)

·        Durr VistaScan Perio (supported directly or via a TWAIN driver)

·        Gendex Denoptix QST

·        Gendex GXPS-500

·        Instrumentarium Express

·        Instrumentarium Express Origo

·        KaVo Scan eXam

·        KaVo Scan eXam One

·        Soredex Digora Optime

Extraoral X-ray devices (Pan and Ceph)

·        Gendex GXDP-300

·        Gendex GXDP-700

·        Gendex Orthoralix 8500/9200 DDE

·        Instrumentarium OP30

·        Instrumentarium OP300 (supported via a TWAIN driver)

·        J. Morita Veraviewepocs 2D (supported via a TWAIN driver or the i-Dixel software bridge)

·        J. Morita Veraviewpocs X800 3D Series (supported via a TWAIN driver or the i-Dixel software bridge)

·        J. Morita Veraview IC5 HD (supported via a TWAIN driver or the i-Dixel software bridge)

·        J. Morita Veraview X800 (supported via a TWAIN driver or the i-Dixel software bridge)

·        KaVo devices

·        KaVo OP3D (supported via an Instrumentarium TWAIN 7.6 driver)

·        Kodak 8000/8100 (supported via a TWAIN driver)

·        Kodak 9000/9300 (supported via a TWAIN driver)

·        Planmeca ProMax (supported via DIDAPI)

·        Planmeca ProOne (supported via DIDAPI)

·        Sirona Dentsply Orthophos SL series (supported via a TWAIN driver)

·        Sirona Dentsply Orthophos XG series (3, 5, Plus, 3D Ready, and 3D; all supported via a TWAIN driver)

·        Vatech PaX-i and Pax-i Plus (supported via a TWAIN driver or Vatech EzDent-i Software Bridge)

·        Carestream Imaging Software Bridge

·        DEXIS Software Bridge

·        DTX Studio Software Bridge

·        J. Morita i-Dixel Software Bridge

·        Romexis Software Bridge

·        ShadeWave Bidirectional Software Bridge

·        Sidexis Software Bridge

·        Vatech EzDent-i Software Bridge

·        File Import (.bmp, .png, .jpg, .tif )

Intraoral/extraoral color photo devices

·        Acteon SOPRO (all models)

·        Air Techniques CamX Polaris (supported via a TWAIN driver)

·        Air Techniques CamX Spectra (supported via a TWAIN driver)

·        Carestream CS1000, CS1200, and CS1500 (supported via a TWAIN driver)

·        DEXIS CariVu

·        DEXIS DEXcam 3

·        DEXIS DEXcam 4

·        DEXIS DEXcam 4 HD

·        Digital Doc IRIS (non-HD)

·        Digital Doc IRIS HD

·        DiscoveryHD Lite (Wired)

·        DiscoveryHD Lite (Wireless)

·        DiscoveryHD Pro (Wired)

·        DiscoveryHD Pro (Wireless)

·        DrsCam (Wired)

·        DrsCam (Wireless)

·        EZ ShotHD (Wired)

·        EZ ShotHD (Wireless)

·        MouthWatch (supported using the Generic Intraoral Camera device in Dentrix Imaging Center)

·        PerfectCam (supported using the Generic Intraoral Camera device in Dentrix Imaging Center; PerfectCam Capture must be installed and configured.)

·        Polaroid (Wired)

·        Polaroid (Wireless)

·        RealCloud HD1

·        SuniCam HD (Wired)

·        SuniCam HD (Wireless)

·        WhicamStory3 (Wired)

·        WhicamStory3 (Wireless)

·        Any USB intraoral camera with buttons that have a joystick/game-port interface

·        Any USB intraoral camera without buttons that has a foot pedal (or a similar triggering device) with a joystick interface

·        Carestream Imaging Software Bridge

·        DEXIS Software Bridge

·        DTX Studio Software Bridge

·        J. Morita i-Dixel Software Bridge

·        Romexis Software Bridge

·        ShadeWave Bidirectional Software Bridge (browser-based, color-matching software)

·        Sidexis Software Bridge

·        File Import (.bmp, .png, .jpg, .tif )

3D volume devices (CBCT)

·        3DIEMME enables seamless integration with RealGUIDE software for patient data transfer.

·        BlueSky Bio One-Way Bridge Integration (allows sharing 3D volumes)

·        J. Morita Veraviewepocs 3D Series (supported via the i-Dixel software bridge)

·        J. Morita Veraview X800 (supported via the i-Dixel software bridge)

·        J. Morita 3D Accuitomo Series (supported via the i-Dixel software bridge)

·        KaVo CBCT devices

·        Nemotec NemoStudio (allows sharing 3D volumes)

·        Owandy CBCT device

·        Owandy Quickvision 3D (allows sharing 3D volumes)

·        Carestream Imaging Software Bridge

·        DEXIS Software Bridge

·        DTX Studio Software Bridge (Dentrix Imaging Center only displays and saves a 2D snapshot of a 3D volume acquired with this software bridge. The full 3D volume may still be viewable in the corresponding third-party software.)

·        ImageWorks Software Bridge

·        J. Morita i-Dixel Software Bridge

·        Quickvision 3D

·        Romexis Software Bridge

·        SICAT One-Way Bridge Integration

·        Sidexis Software Bridge

·        VixWin Software Bridge – Added support for acquiring 3D volumes from Gendex CBCT devices.

·        Vatech Ez 3D-i Software Bridge

·        File Import (.bmp, .png, .jpg, .tif)

CAD/CAM scan devices

·        Carestream CS7600

·        DTX Studio Software Bridge

·        Romexis Software Bridge

·        File Import (.stl, .ply)

Important:

·        If you want to use a device other than a DEXIS device, additional costs may be required, such as the purchase of drivers, to integrate that device with Dentrix Imaging Center. Before you purchase the Dentrix Imaging add-on or a particular device that you want to use with Dentrix Imaging Center, consult the manufacturer of that device to verify if there will be costs to get that device working with Dentrix Imaging Center.

·        Some, but not all, devices have been tested using a TWAIN driver. Using a TWAIN driver with certain devices might have unexpected results.