Supported acquisition devices

Dentrix Imaging supports the following acquisition devices.

Intraoral X-ray devices

A2Z Imaging DUO

Acteon Sopro SOPIX Gen 1 (supported directly or via a TWAIN driver)

Acteon Sopro SOPIX Gen 2

Apteryx Tuxedo sensor (supported using e2v as the acquisition device) or (previous version is Hamamatsu, which is also supported directly)

Note: Tuxedo sensors that were manufactured prior to 2019 are Hamamatsu devices (LED Dental Tuxedo sensors), which are supported using Hamamatsu as the acquisition device. Contact LED Dental to verify if your Tuxedo sensor is a Hamamatsu device or an e2v device.

Brassler GEM sensor

CARINA sensor

DentalSensors.com Apex

Dentimax Dream sensor (supported using e2v as the acquisition device)

Dentsply Sirona XIOS AE Select (supported directly using "Sirona / Schick USB 3 / AE" as the acquisition device; or supported via the SiTWAIN driver)

Dentsply Sirona XIOS XG Select (supported directly using "Sirona / Schick USB 3 / AE" as the acquisition device; or supported via the SiTWAIN driver)

Dentsply Sirona XIOS XG Supreme (supported directly using "Sirona / Schick USB 3 / AE" as the acquisition device; supported directly using "Schick 33 / Xios XG" as the acquisition device with a USB 2.0 interface; or supported via the SiTWAIN driver)

DEXIS Platinum (supported directly or via GxPicture)

DEXIS Titanium (supported directly or via GxPicture)

EVA Select sensor (supported using e2v as the acquisition device or via a TWAIN driver)

FTG DC-Air/CEFLA

Gendex/KaVo IO (supported using the GxPicture, KaVo devices, DTX Studio Bridge, or GxTWAIN as the acquisition device)

Gendex GXS-700

Gendex Visualix eHD (only compatible with Windows 7)

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging Center on a computer running Windows 7.

Gendex Visualix GX-S

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging Center on a computer running Windows XP.

GxPicture devices

Hamamatsu

Note: Tuxedo sensors manufactured prior to 2019 are Hamamatsu devices.

Handy HDR-360/460 and HDR-500/600

ImageWorks EVA Select (supported directly as an e2v sensor or via a TWAIN driver)

InstaRay sensor (supported using Hamamatsu as the acquisition device)

iRay Pluto sensor

iRay Woodpecker/Eighteeth sensor

Jazz (supported via a TWAIN driver)

Jazz Solo sensor

KaVo Dig eXam

KaVo IXS (supported directly or via GxPicture)

Kodak/Carestream 5000 series and 6000 series (supported directly or via a TWAIN driver)

LED Dental Tuxedo (supported using Hamamatsu as the acquisition device)

Note: Tuxedo sensors manufactured in or before 2019 are e2v devices (Apteryx Tuxedo sensors), which are supported using e2v as the acquisition device. Contact LED Dental to verify if your Tuxedo sensor is a Hamamatsu device or an e2v device.

Midmark Progeny ClearVision (supported directly or via a TWAIN driver)

Owandy ONE and OPTEO

Planmeca ProSensor (supported via DIDAPI)

Planmeca ProSensor HD (supported via DIDAPI)

Polaroid KEREN HD-S (supported via a TWAIN driver)

QuickRay (supported using e2v as the acquisition device)

QuickRay HD sensor (supported using Hamamatsu as the acquisition device)

Remedi (supported using Hamamatsu as acquisition device)

Schick 33 (from Dentsply Sirona; supported directly using "Sirona/Schick USB 3/AE" as the acquisition device with a USB 2.0/3.0 interface; supported directly using "Schick 33/Xios XG" as the acquisition device with a USB 2.0 interface; via the SiTWAIN driver with a USB 2.0/3.0 interface; or supported via the "CDR Intra-oral X-rat Acquisition" TWAIN driver with USB 2.0 interface)supported via a TWAIN driver)

Schick AE (from Dentsply Sirona; supported directly using "Sirona/Schick USB 3/AE" as the acquisition device; or supported via the TWAIN driver)

Schick CDR 2000 (supported directly or via a TWAIN driver; only compatible with Windows 7 32-bit)

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging on a computer running Windows 7 32-bit.

Schick 33/Xios XG (supported directly or via a TWAIN driver)

Note: The device filter defaults are set automatically. When you select the Schick 33 device for the first time, the following default settings are used for filtering: custom Schick filter is set to "General," Apply Enhancement is set to "Not Enhanced," and Schick 33 is set to "Binned" operation.

Schick Elite (from Dentsply Sirona; supported directly using "Sirona/Schick USB 3/AE" as the acquisition device with a USB 2.0/3.0 interface; supported directly using "Schick CDR/Elite" as the acquisition device with a USB 2.0 interface; or supported via the SiTWAIN driver)

Schick HS (from Dentsply Sirona; supported directly or via a TWAIN driver; only compatible with Windows 7)

Important: This device is not officially supported because it is only compatible with an unsupported operating system. However, this device may function with Dentrix Imaging on a computer running Windows 7 32-bit.

Sirona/Schick USB 3/AE (supported directly or via a TWAIN driver) – Added image filtering options during image acquisition. These filtering options enhance the flexibility and quality control available to users when they are capturing images.

Sirona IOSS – Added sharpness settings for filters. Filters for the Supreme and Velocity family of sensors allow users to set a sharpness value between 0 and 100. A new Sirona section was added to the agent preferences to store these values.

SOPIX Gen 2 sensors

SOTA Clio/Clio prime sensor (also supported using e2v as the acquisition device)

Suni (most models supported via a TWAIN driver; contact the support department to verify)

Teledyne e2v

Note: e2v sensors are rebranded and sold by many companies under their specific brand names. The following devices are supported using e2v as the acquisition device:

Apteryx Tuxedo sensor (previous version is Hamamatsu, which is also supported directly)

Dentimax Dream sensor

EVA Select sensor

QuickRay sensor

SOTA Clio/Clio Prime sensor

XDR X-ray sensor

Vatech HD sensor (supported directly via a TWAIN driver or Vatech EzDent-i software bridge)

Note: Vatech HD sensors are rebranded and sold by Digital DOC under their brand name. The Digital DOC© Blu is supported using Vatech as the acquisition device.

Vatech Wave sensor (supported directly via a TWAIN driver or Vatech EzDent-i software bridge)

Video Dental Concepts QuickRay HD

XDR sensor

Carestream Imaging software bridge

DEXIS software bridge

DTX Studio software bridge

ImageWorks software bridge

J. Morita i-Dixel software bridge

MEDIT software bridge

Romexis software bridge

ShadeWave Bidirectional software bridge

Sidexis software bridge

Vatech EzDent-i software bridge

VixWin software bridge

File Import (.bmp, .png, .jpg, .tif )

Intraoral/extraoral X-ray Phosphor Plate devices

Acteon Sopro PSPIX

Air Techniques ScanX Classic

Air Techniques ScanX Duo

Air Techniques ScanX IO

Air Techniques ScanX Swift

Carestream CS7600

Durr VistaScan (supported directly with VistaEasy or VisionX Connect  for Windows 11 or via a TWAIN driver)

Durr VistaScan Combi+ (supported directly with VistaEasy or VisionX Connect  for Windows 11 or via a TWAIN driver)

Durr VistaScan Mini (supported directly with VistaEasy or VisionX Connect  for Windows 11 or via a TWAIN driver)

Durr VistaScan Perio (supported directly with VistaEasy or VisionX Connect  for Windows 11 or via a TWAIN driver)

Gendex Denoptix QST

Gendex GXPS-500

GxPicture devices

Instrumentarium Express

Instrumentarium Express Origo

KaVo OP3D (supported via KaVo devices or TWAIN driver)

KaVo OP30 (supported via KaVo devices or TWAIN driver)

KaVo Scan eXam

KaVo Scan eXam One

Soredex Digora Optime

Extraoral X-ray devices (Pan and Ceph)

Dentsply Sirona Orthophos SL Series (supported via a TWAIN driver)

Dentsply Sirona Orthophos XG 3, 5, Plus, 3D Ready, and 3D (supported via a TWAIN driver)

Gendex GXDP-300

Gendex GXDP-700

Gendex Orthoralix 8500/9200 DDE

Instrumentarium OP30

Instrumentarium OP300 (supported via a TWAIN driver)

J. Morita Veraviewepocs 2D (supported via a TWAIN driver or the i-Dixel software bridge)

J. Morita Veraviewpocs X800 3D Series (supported via a TWAIN driver or the i-Dixell software bridge)

J. Morita Veraview IC5 HD (supported via a TWAIN driver or the i-Dixell software bridge)

J. Morita Veraview X800 (supported via a TWAIN driver or the i-Dixel software bridge)

KaVo OP3D (supported via a TWAIN driver or using "Kavo Devices" as the acquisition device)

KaVo ProXam 2D, 3D,3DQ, and Ceph

Kodak 8000/8100 (supported via a TWAIN driver)

Kodak 9000/9300 (supported via a TWAIN driver)

Owandy Pan/Ceph (direct 2D acquisition)

Planmeca ProLine (supported via DIDAPI)

Planmeca ProMax (supported via DIDAPI)

Planmeca ProOne (supported via DIDAPI)

Sirona Dentsply Orthophos SL series (supported via a TWAIN driver)

Sirona Dentsply Orthophos XG series (3, 5, Plus, 3D Ready, and 3D; all supported via a TWAIN driver)

Vatech PaX-i and Pax-i Plus (supported via a TWAIN driver or Vatech EzDent-i software bridge)

Carestream Imaging software bridge

DEXIS software bridge

DTX Studio software bridge

J. Morita i-Dixel software bridge

Romexis software bridge

ShadeWave Bidirectional software bridge

Sidexis software bridge

Vatech EzDent-i software bridge

VixWin software bridge

File Import (.bmp, .png, .jpg, .tif )

Intraoral/extraoral color photo devices

Acteon SOPRO (all models)

Air Techniques CamX Polaris (supported via a TWAIN driver)

Air Techniques CamX Spectra (supported via a TWAIN driver)

Carestream CS1000, CS1200, and CS1500 (supported via a TWAIN driver)

DEXIS CariVu

DEXIS DEXcam 3

DEXIS DEXcam 4

DEXIS DEXcam 4 HD

Digital Doc IRIS (non-HD)

Digital Doc IRIS HD

DiscoveryHD Lite (Wired)

DiscoveryHD Lite (Wireless)

DiscoveryHD Pro (Wired)

DiscoveryHD Pro (Wireless)

DrsCam (Wired)

DrsCam (Wireless)

EZ ShotHD (Wired)

EZ ShotHD (Wireless)

MouthWatch (supported using the Generic Intraoral Camera device in Dentrix Imaging; MouthWatch Capture must be installed and configured)

PerfectCam (supported using Generic Intraoral Camera as the acquisition device; the PerfectCam utility must be installed and configured)

Polaroid (Wired)

Polaroid (Wireless)

RealCloud HD1

SuniCam HD (Wired)

SuniCam HD (Wireless)

WhicamStory3 (Wired)

WhicamStory3 (Wireless)

Any USB intraoral camera with buttons that have a joystick/game-port interface

Any USB intraoral camera without buttons that has a foot pedal (or a similar triggering device) with a joystick interface

Carestream Imaging software bridge

DEXIS software bridge

DTX Studio software bridge

J. Morita i-Dixel software bridge

Romexis sftware bridge

ShadeWave Bidirectional software bridge (browser-based, color-matching software)

Sidexis software bridge

File Import (.bmp, .png, .jpg, .tif )

3D volume devices (CBCT)

3DIEMME enables seamless integration with RealGUIDE software for patient data transfer.

BlueSky Bio One-Way Bridge Integration (allows sharing 3D volumes)

Gendex GXDP-700 S and SC (supported via the VixWin software bridge)

J. Morita Veraviewepocs 3D Series (supported via the i-Dixel software bridge)

J. Morita Veraview X800 (supported via the i-Dixel software bridge)

J. Morita 3D Accuitomo Series (supported via the i-Dixel software bridge)

KaVo 3D CBCT devices (supported directly using KaVo devices as the acquisition device; supported via the DEXIS software bridge; or supported via the VixWin software bridge depending on model and existing configuration)

Nemotec NemoStudio (allows sharing 3D volumes)

Owandy I-Max 3D, 3D Pro, Ceph 3D, and 3D Ceph Pro

Acteon AIS software bridge

Carestream Imaging software bridge

DEXIS software bridge

DTX Studio software bridge (Dentrix Imaging only displays and saves a 2D snapshot of a 3D volume acquired with this software bridge. The full 3D volume may still be viewable in the corresponding third-party software.)

ImageWorks software bridge

J. Morita i-Dixel software bridge

Quickvision 3D

Romexis software bridge

Sidexis software bridge

Vatech Ez 3D-i software bridge

VixWin software bridge – Added support for acquiring 3D volumes from Gendex CBCT devices.

File Import (.bmp, .png, .jpg, .tif)

CAD/CAM scan devices

3Shape Software Bridge

Dentsply Sirona DS Core software bridge

DTX Studio software bridge

Note: The purchase and installation of the DTX Studio Clinic imaging program is required.

Medit Software bridge

Romexis software bridge

File Import (.stl, .ply)

Important:

If you want to use a device other than a DEXIS device, additional costs may be required, such as the purchase of drivers, to integrate that device with Dentrix Imaging. Before you purchase the Dentrix Imaging add-on or a particular device that you want to use with Dentrix Imaging, consult the manufacturer of that device to verify if there will be costs to get that device working with Dentrix Imaging.

Some, but not all, devices have been tested using a TWAIN driver. Using a TWAIN driver with certain devices might have unexpected results.